Length: | 17m |
---|---|
Transport Package: | Standard Export Packaging |
Specification: | 20M LENGTH |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Construction: | Painting cabin with air extractionthrough the floor, ceiling ventilation and intake air heating construction of housing pre-fabricated elements for installation in an existing shed further with working pit arranged in the middle and its ventilation. |
|
Operational modes: | Painting with exhaust air and heated additional air | |
Drying with circulating air and fresh air component | ||
Effective space: | 17,00 meter length | |
5,00 meter width | ||
5,50 meter height to the under edge of filter ceiling and over edge of housing steel construction approximate 6,38 meter height. |
||
Machine space dimensions: | 2 sets of aggregates arranged at the side of spraying booth, each: | |
Approximate 3,73 meter length | ||
Approximate 1,45 meter width | ||
Approximate 2,90 meter height | ||
Floor space: | 85 m ² | |
Volume of effective space: | 467 m ³ | |
Exhaust air capacity: | 2 x 30.000 m ³/h = 60.000 m³/h | |
Exhaust motor: | 2 x 1 x 11 kW - 960 min -1 | |
Intake capacity: | 2 x 30.000 m ³/h = 60.000 m³/h | |
Intake motor: | 2 x 1 x 11 kW - 960 min -1 | |
Room over pressure: | Adjustable with 2 regulating flaps, monitored by pressure gauge. | |
Sinking speed: | Approx. 0,22 m/sec. Without prefabricated part in total room. | |
Change of air: | Approx. 128 x/h | |
Thermal energy: | Light oil. | |
Alternatively nature gas or LPG gas as option. | ||
Heating of air: | Indirectly via air heater with blower burner | |
Maximum heat output: | 2 x 315 kW = 630 kW | |
Spray temperature: | Approx. 20 - 22° C, optional adjustable | |
Up to approximate 80° C, controllable re-circulated air | ||
Drying temperature: | Up to approximate 80° C, controllable re-circulated air | |
Temperature regulation: | Optional adjustable, regulated automatically, | |
with adjustment of nominal value and digital information of actual value. | ||
Temperature control | according to DIN 4794 also automatic follower control in order and 3440 Via temperature regulator and limiting thermostat with lock also automatic follower control in order |
|
Exhaust system: | Via ground channel under floor, beside the vehicle, | |
Floor grating: | Galvanized gratings | |
wheel loading 1500 Kg ( 20 x 20 cm ) | ||
2 channels of each approximate 16,00 x 0,80 meter | ||
Exhaust air filtering: | Via drying separation with non-inflammable disposable filter mats according to DIN 4102 | |
Intake air filtering: | a) Through pre-filtering units with intake air u
b) Through ceiling- mounted fine filters with large surface frames for quick changing, CC-600 fine filters, filter class F 5 EN 779 |
|
Illumination above: | Protective system IP 65 - 3.168 watt lateral mounted below the filter ceiling Total amount of lamps 22 units, each with 4 x 36 watt |
|
Illumination at the bottom: | Side wall-lamps - 1.728 watt with total 24 lamps of 2 x 36 watt each for side wall mounting. |
|
Gate assembly: | One main door for drive in 4,27(W) x 5,38(H) meter | |
2 personnel doors : 0,8(W) x 2,0(H) meter, with windows. | ||
Length of connections measured over edge floor: | Exhaust air lines approx. + 10,00 meter over edge Suction lines approx. + 8,00 meter over edge Flue pipes VA approx. + 9,00 meter over edge ( Depending on the height of hall, perhaps further channels will be necessary. ) |
|
Connected loads: | Approx. 50 kW Operating voltage: 400 volts, 50 Hz. Control voltage: 230 volts, 50 Hz |